Menu AuthGuardHelp centre
Portuguêsauthguard.pt

Troubleshooting · Edge appliance

Edge appliance warnings and errors (modules, audit, configuration)

  • 1 min read
  • Edge · SaaS · Self-hosted

Symptom and fix

Warning or errorCauseWhat to do
«No heartbeat»The appliance is not reportingCheck that the service is running and outbound port 443 works (proxy, firewall, DNS)
«Module failed»A module stoppedCheck the appliance's logs; the agent restarts the module
edge_module_refusedThe module is not admitted on this applianceIn this version the appliance runs only the privileged access module; other modules do not start
«Audit queue above 80 %»Audit is not being sentCheck the connection; the queue drains when it returns
«Configuration not applied»The configuration revision has not been applied for 15 minutesCheck the logs; restart the service if needed
edge_audit_rejectedAn audit segment is not signed by this appliance's audit keyTreat it as an incident
«Audit chain discontinuity» (edge_audit_discontinuity)An audit upload does not continue the stored chainTreat it as an incident; do not delete appliance data
edge_request_malformedAn invalid request from the appliance, usually an old versionUpdate the appliance

What about the directory and RADIUS modules?

The appliance runs only privileged access, so the configuration dialog offers only that module. RADIUS and directory work from the central service. See What is not supported yet.

When to escalate

A discontinuity or a rejection in the audit chain may indicate tampering. Isolate the appliance, keep the logs and contact support and your security team.

Error codes in this article

Article referencets-edge-errorsquote it to support to identify this article. Checked against the product at commit 5f6607a8.